English
Language : 

E202075_HD404889 Datasheet, PDF (64/202 Pages) Renesas Technology Corp – Low-Voltage AS Microcomputers with On-Chip LCD Circuit
HD404889/HD404899/HD404878/HD404868 Series
System Clock Gear Function
The MCU has a built-in system clock gear function that allows the system clock divided by 4 or by 32 to be
selected by software for the instruction execution time. Efficient power consumption can be achieved by
operating at the divided-by-4 rate when high-speed processing is needed, and at the divided-by-32 rate at
the other times. Figure 23 shows the system clock conversion method.
System clock conversion from division-by-4 to division-by-32 is performed as follows. First, make the
division-by-32 setting (SSR0 write), then set the gear enable flag (GEF: $021,3). This flag is used to
distinguish between gear conversion and a transition to standby mode. Next, execute an SBY instruction.
When the gear enable flag is not set, standby mode is entered; when this flag is set, gear conversion mode
is entered. In this case a transition is made to standby mode for the duration of the gear conversion, but
after the synchronization time has elapsed, a transition is made automatically to active mode. As soon as
the transition is made to active mode, the gear enable flag is reset.
The same procedure is used for conversion from division-by-32 to division-by-4.
Clear all interrupts, then disable interrupts, before carrying out gear conversion. Incorrect operation may
result if an interrupt is generated during gear conversion.
62