English
Language : 

E202075_HD404889 Datasheet, PDF (62/202 Pages) Renesas Technology Corp – Low-Voltage AS Microcomputers with On-Chip LCD Circuit
HD404889/HD404899/HD404878/HD404868 Series
Usage notes:
In watch mode and subactive mode, an interrupt will not be detected correctly if the INT0 or WU0 to WU3
high or low-level period is shorter than the interrupt frame period.
The MCU’s edge sensing method is shown in figure 20. The MCU samples the INT0 and WU0 to WU3
signals at regular intervals, and if consecutive sampled values change from high to low, it determines that a
falling edge has been generated.
Interrupt detection errors occur since this sampling is performed at the interrupt frame period. If the high-
level period of the INT0 or WU0 to WU3 signal is within an interrupt frame, as shown in figure 21 (a), the
signal will be low at point A and point B, with the result that the falling edge will not be recognized.
Similarly, If the low-level period of the INT0 or WU0 to WU3 signal is within an interrupt frame, as shown
in figure 21 (b), the signal will be high at point A and point B, with the result that the falling edge will not
be recognized.
In watch mode and subactive mode, therefore, ensure that the high-level and low-level periods of the INT0
and WU0 to WU3 signals is at least as long as the interrupt frame period.
INT0
or
WU0 to WU3
Sampling
High
Low
Low
Figure 20 Edge Sensing Method
(a) High-level mode
(b) Low-level mode
INT0 or
WU0 to WU3
INT0 or
WU0 to WU3
Interrupt frame Point A: Low
Point B: Low
Interrupt frame Point A: High
Point B: High
Figure 21 Sampling Examples
60