English
Language : 

M30218 Datasheet, PDF (57/179 Pages) Mitsubishi Electric Semiconductor – M30218 Group
FLD controller
Mitsubishi microcomputers
M30218 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Toff1 time set register
b7
b0
Symbol
TOFF1
Address
035416
When reset
FF16
Function
Counts Toff1 time. Count source is selected by Tdisp counter count source
select bit.
Values that can be set R W
3 to FF16
Toff2 time set register
b7
b0
Symbol
TOFF2
Address
035616
When reset
FF16
Function
Counts Toff2 time. Count source is selected by Tdisp counter count source
select bit.
Values that can be set R W
3 to FF16
FLD data pointer
b7
b0
Symbol
FLDDP
Address
035816
When reset
indeterminate
Function
Counts FLD output timing. Set this register to “FLD output data - 1 ”.
Note: Reading the FLD data pointer takes out the count at that moment.
Values that can be set R W
1 to 1F16
Port P2 FLD / port switch register
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
P2FPR
Address
035916
When reset
0016
Bit symbol
Bit name
P2FPR0
Port P20 FLD/port switch bit
P2FPR1 Port P21 FLD/port switch bit
P2FPR2
Port P22 FLD/port switch bit
P2FPR3
Port P23 FLD/port switch bit
P2FPR4
Port P24 FLD/port switch bit
P2FPR5
Port P25 FLD/port switch bit
P2FPR6
Port P26 FLD/port switch bit
P2FPR7
Port P27 FLD/port switch bit
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
0 : Normal port
1 : FLD output port
Function
RW
Figure KA-2A. FLDC-related Register(2)
56