English
Language : 

M30218 Datasheet, PDF (109/179 Pages) Mitsubishi Electric Semiconductor – M30218 Group
Serial I/O2
Mitsubishi microcomputers
M30218 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Handshake Signal
There are five types of handshake signal : SSTB2 output, SBUSY2 input/output, and SRDY2 input/output.
(1) SSTB2 output signal
The SSTB2 output is a signal to inform an end of transmission/reception to the serial transfer destina-
tion. The SSTB2 output signal can be used only when the internal synchronous clock is selected. In the
initial status [ serial I/O initialization bit (bit 4 of address 034216) = “0” ], the SSTB2 output goes to “L”
__________
(bits 2, 3 of address 034216=11), or the SSTB2 output goes to “H” (bits 2, 3 of address 034216=10).
At the end of transmit/receive operation, after the all data of the serial I/O2 register (address 034616) is
_________
output from SOUT2, SSTB2 output is “H” (or SSTB2 output is “L”) in the period of 1 cycle of the transfer clock.
Furthermore, after 1 cycle, the serial transfer status flag (bit 5 of address 034416) is reset to “0”.
In the automatic transfer serial I/O mode, whether the SSTB2 output is to be output at an end of each 1-byte
data or after completion of transfer of all data can be selected by the SBUSY2 output • SSTB2 output function
select bit (bit 4 of address 034416).
•Serial operation used SSTB2 output
Operation mode
Transfer clock
SSTB2 output timing
: 8-bit serial I/O mode
: Internal synchronous clock
: Each 1-byte data
Tc
Internal clock
Serial transfer status flag "1"
(bit 5 at address 034416) "0"
SCLK2i
(i=1, 2)(output)
"H"
SSTB2(output)
"L"
SOUT2
D0 D1 D2 D3 D4 D5 D6 D7
Tc : Internal synchronous clock is selected by bits 5 to 7 of address 034816
•Serial operation used SSTB2 output
Operation mode
Transfer clock
SSTB2 output timing
Tc
: Automatic transfer serial I/O mode
: Internal synchronous clock
: Each transfer of all data
Automatic
transfer interval
Internal clock
Serial transfer status flag "1"
(bit 5 at address 034416) "0"
SCLK2i
(i=1, 2)(output)
"H"
SSTB2(output)
"L"
SOUT2
D0 D1 D2 D3 D4 D5 D6 D7
D0 D1 D2 D3 D4 D5 D6 D7
Tc : Internal synchronous clock is selected by bits 5 to 7 of address 034816
Figure GA-6. SSTB2 Output Operation
108