Appendix Standard Serial I/O Mode 1 (Flash Memory Version) SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Full Status Check
Results from executed erase and program operations can be known by running a full status check. Figure
1.32.19 shows a flowchart of the full status check and explains how to remedy errors which occur.
Read status register
YES
SR4=1 and SR5
=1 ?
Command
sequence error
NO
SR5=0? NO Block erase error
YES
SR4=0? NO
Program error
YES
End (block erase, program)
Execute the clear status register command (5016)
to clear the status register. Try performing the
operation one more time after confirming that the
command is entered correctly.
Should a block erase error occur, the block in error
cannot be used.
Execute the read lock bit status command (7116)
to see if the block is locked. After removing lock,
execute write operation in the same way. If the
error still occurs, the page in error cannot be
used.
Note: When one of SR5 to SR4 is set to 1, none of the program, erase all blocks, and
block erase commands is accepted. Execute the clear status register command
(5016) before executing these commands.
Figure 1.32.19. Full status check flowchart and remedial procedure for errors
193