English
Language : 

MT40A512M16HA-083EIT Datasheet, PDF (243/373 Pages) Micron Technology – Programmable data strobe preambles
8Gb: x4, x8, x16 DDR4 SDRAM
WRITE Operation
Figure 193: WRITE (BC4-Fixed) with 1tCK Preamble and DBI
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T17
CK_c
CK_t
Command WRITE
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
DES
WL = AL + CWL = 9
2 Clocks
tWR
tWTR
Address BGa
Address
Bank,
Col n
BC4 (Fixed) Opertaion
DQS_t,
DQS_c
DQ
DI DI DI DI
n n+1 n+2 n+3
DBI_n
DI DI DI DI
n n+1 n+2 n+3
Transitioning Data
Don’t Care
Notes:
1. BC4 = fixed, WL = 9 (CWL = 9, AL = 0 ), Preamble = 1tCK.
2. DI n = data-in from column n.
3. DES commands are shown for ease of illustration; other commands may be valid at
these times.
4. BC4 setting activated by MR0[1:0] = 10.
5. CA parity = Disable, CS to CA latency = Disable, Write DBI = Enabled, Write CRC = Disa-
bled.
09005aef861d1d4a
8gb_ddr4_dram.pdf - Rev. G 1/17 EN
243
Micron Technology, Inc. reserves the right to change products or specifications without notice.
‹ 2015 Micron Technology, Inc. All rights reserved.