Port Timing
(Operating Conditions apply; CL = 50 pF)
Parameter
Symbol
Limits
Unit
min max
Port data valid from TRCLK 1)
t1 CC −
13 ns
1) Port data is output with respect to the FPI clock. The TRCLK is used as a reference here since the FPI clock
is not available as an external pin and TRCLK is same frequency as CPU clock. Port lines maintain its state
for at least 2 CPU clocks.
TRCLK
FPI_CLK
Port Lines
t1
Old State
Figure 26 Port Timing
New State