English
Language : 

TC1130 Datasheet, PDF (77/113 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1130
Operating Condition
The following operating conditions must not be exceeded in order to ensure correct
operation of the TC1130. All parameters specified in the following table refer to these
operating conditions, unless otherwise noticed.
Parameter
Symbol Limit Values
min.
max.
Unit Notes
Conditions
Digital supply voltage
VDDC
1.43
VDDP
3.14
Digital ground voltage
VSS
Digital core supply current IDD
Ambient temperature under TA
-40
bias
CPU clock
fSYS
–1)
Overload current
IOV
-1
-3
Short circuit current
ISC
-1
-3
Absolute sum of overload + Σ|IOV| + –
short circuit currents
|ISC|
1.58
3.47
0
525
+85
150
1
3
1
3
|50|
|100|
V
V
V–
mA
°C –
MHz
mA
–
2)3)
duty cycle ≤ 25%
mA 4)
duty cycle ≤ 25%
mA 3)
duty cycle ≤ 25%
Inactive device pin current IID
(VDD = VDDP = 0)
External load capacitance CL
ESD strength
-1
1
–
50
2000 –
mA –
pF
V Human Body
Model (HBM)
1) The TC1130 uses a static design, so the minimum operation frequency is 0 MHz. Due to test time restriction
no lower frequency boundary is tested, however.
2) Overload conditions occur if the standard operating conditions are exceeded, i.e. the voltage on any pin
exceeds the specified range (i.e. VOV > VDDP + 0.5 V or VOV < VSS - 0.5 V). The absolute sum of input
overload currents on all digital IO pins may not exceed 50 mA. The supply voltage must remain within the
specified limits.
3) Not 100% tested, guaranteed by design and characterization.
Data Sheet
73
V0.3, 2003-09