RF60 CRYSTAL-LESS SOC TRANSMITTER v1.0
SFR Definition 23.2. BOOT_FLAGS
Bit
Name
7
6
5
RESERVED
Type R/W
R/W
R/W
Reset
0
0
0
4
CODE_
RUN_
POR
R/W
0
3
RE-
SERVED
R/W
0
2
BOOT_
FAIL_
SYS
R/W
0
1
BOOT_
DONE_
SYS
R/W
0
0
CODE_
RUN_SYS
R/W
0
SFR Address = 0xDD
Bit Name
Function
7:5 RESERVED Reserved.
4 CODE_ Run user code in RAM.
RUN_ Same functionality as CODE_RUN_SYS.
POR
3 RESERVED Reserved.
2 BOOT_ Boot loading process failed.
FAIL_
SYS
This is an information flag, independent of the BOOT_DONE_SYS. This bit is set
when the boot status XDATA variable bBoot_BootStat is not equal to 0x00, signal-
ling error during boot.
It is recommended that the user code reads this bit and possibly make decisions
whether to continue with the execution of the loaded RAM code, which might not be
complete, or signal to a user a problem, by, for example, blinking LED in some not-
ordinary fashion.
1 BOOT_ Boot routine finished flag.
DONE_ Always set to 1 at the end of the boot.
SYS
0 CODE_ Run User Code in RAM.
RUN_SYS Used for Factory and User program states, ignored in Run state. When this bit is set
the boot routine will jump to CODE address 0x0000. Forced by the debugging chain if
the device is connected to the IDE.
Tel: +86-755-82973805
Fax: +86-755-82973550
84
E-mail: sales@hoperf.com http://www.hoperf.com