English
Language : 

GS4911B Datasheet, PDF (26/113 Pages) Gennum Corporation – HD/SD/Graphics Clock and Timing Generator with GENLOCK
GS4911B/GS4910B Data Sheet
Table 1-3: Output Timing Signals (Continued)
Signal Name
Description
Default Output Pin
V Sync
V Blanking
F Sync
The V Sync timing signal has a leading edge at the start of the vertical sync
pulse. Its length is determined by the selected video standard (see Table 1-2),
or according to custom timing parameters programmed in the host interface
(see Section 3.10 on page 74).
The leading edge of V Sync is nominally simultaneous with the leading edge of
the first broad pulse.
When in Genlock mode, the output V Sync signal will be phase locked to the
reference VSYNC input. This timing may be offset using the Genlock Offset
registers beginning at address 1Bh of the host interface (see Section 3.2.1.1 on
page 37).
By default, after system reset, the polarity of the V Sync signal output will be
active LOW. The polarity may be selected as active HIGH by programming the
Polarity register at address 56h of the host interface (see Section 3.12.3 on
page 79).
TIMING_OUT_3
The V Blanking signal is used to indicate the portion of the video field/frame not
containing active video lines.
The V Blanking signal will be LOW (default polarity) for the portion of the
field/frame containing valid video data, and will be HIGH throughout the vertical
blanking period.
The width of this signal will be determined by the selected video standard (see
Table 1-2), or according to custom timing parameters programmed in the host
interface (see Section 3.10 on page 74).
When in Genlock mode, the output V Blanking signal will be phase locked to the
reference VSYNC input. This timing may be offset using the Genlock Offset
registers beginning at address 1Bh of the host interface (see Section 3.2.1.1 on
page 37).
The default polarity of this signal may be inverted by programming the Polarity
register at address 56h of the host interface (see Section 3.12.3 on page 79).
NOTE: When VID_STD = 4, 6, or 8, the Vblank output pulse width is 2 lines too
long for field 1 and 1 line too short for field 2 when compared to the digital timing
defined in ITU-R BT.656 and ITU-R BT.799.
TIMING_OUT_4
The F Sync signal is used to indicate field 1 and field 2 for interlaced video
formats.
The F Sync signal will be HIGH (default polarity) for the entire period of field 1. It
will be LOW for all lines in field 2 and for all lines in progressive scan systems.
The width and timing of this signal will be determined by the V Sync parameters
of the selected video standard (see Table 1-2), or according to custom V Sync
timing parameters programmed in the host interface (see Section 3.10 on
page 74). The F Sync signal always changes state on the leading edge of V
Sync.
When in Genlock mode, the output F Sync signal will be phase locked to the
reference FSYNC input. This timing may be offset using the Genlock Offset
registers beginning at address 1Bh of the host interface (see Section 3.2.1.1 on
page 37).
The default polarity of this signal may be inverted by programming the Polarity
register at address 56h of the host interface (see Section 3.12.3 on page 79).
TIMING_OUT_5
36655 - 2 April 2006
26 of 113