MC3630 3-Axis Accelerometer
Preliminary Datasheet
(0x29) Trigger Count Register/SDR configuration
This register selects the number of samples to be taken after the one-shot trigger is started.
Addr
0x29
Bit
Name
7
6
5
4
3
2
1
0
POR Value R/W
TRIGC TRIGC[7] TRIGC[6] TRIGC[5] TRIGC[4] TRIGC[3] TRIGC[2] TRIGC[1] TRIGC[0] 00000000 WS
Bit
[7:0]
Name
Description
TRIGC[7:0]
Non-Software Defined rate (default)
Selects the number of samples to be captured after the
one-shot trigger is started. Range from 1 to 254. When
value 255 is chosen, the device will run continuously until
the mode in register 0x10 is changed.
Software Defined rate
Shadow register accessible via Rate Register 1
(0x11[6:4]). Please refer to register 0x11 definition and
application note AN-002 for configurability.
Table 39. Trigger/Software Defined Rate Register Settings
mCube Proprietary
© 2016 mCube Inc. All rights Reserved
APS-048-0047v1.2
73 / 83