MC3630 Datasheet, PDF (49/83 Pages) –
MC3630 3-Axis Accelerometer
Preliminary Datasheet
110
SWAKE Use Sniff logic, main XYZ
pipeline and optional FIFO at
the same time; highest power
consumption
111
TRIG
Trigger mode, 1 to 254
samples or continuous, return
to sleep upon completion.
3
RESV
Reserved
4
X_AXIS_PD 0: X-axis is enabled.
1: X-axis is disabled.
5
Y_AXIS_PD 0: Y-axis is enabled.
1: Y-axis is disabled.
6
Z_AXIS_PD 0: Z-axis is enabled.
1: Z-axis is disabled.
7
TRIG_CMD Setting this bit will execute a one-shot trigger mode where 1 to
254 samples are acquired (or the device will continuously
sample if the value is 255). The number of samples is specified
by the TRIG_COUNT in register 0x29. TRIG mode can only be
started from STANDBY. Unless the value is 255, after the
number of samples is completed, the device will return to
STANDBY mode.
Table 21. Mode Control Register Settings
mCube Proprietary
© 2016 mCube Inc. All rights Reserved
APS-048-0047v1.2
49 / 83