010
SNIFF Threshold, Y-axis
SNIFF_TH_Y[5:0], unsigned
threshold value 0 to 63 (independent
from X and Z thresholds).
011
SNIFF Threshold, Z-axis
SNIFF_TH_Z[5:0], unsigned
threshold value 0 to 63 (independent
from X and Y thresholds).
100
None
101
SNIFF Detection Count, X-axis
SNIFF_X_COUNT[5:0], unsigned
SNIFF event count, 1 to 62 events,
independent from other channels.
The detection count is COUNT-1 for
the desired number of events (for 1
event = 1-1 => 0 loaded into
register).
110
SNIFF Detection Count, Y-axis
SNIFF_Y_COUNT[5:0], unsigned
SNIFF event count, 1 to 62 events,
independent from other channels.
The detection count is COUNT-1 for
the desired number of events (for 1
event = 1-1 => 0 loaded into
register).
111
SNIFF Detection Count, Z-axis
SNIFF_Z_COUNT[5:0], unsigned
SNIFF event count, 1 to 62 events,
independent from other channels.
The detection count is COUNT-1 for
the desired number of events (for 1
event = 1-1 => 0 loaded into
register).
mCube Proprietary
© 2016 mCube Inc. All rights Reserved
APS-048-0047v1.2
55 / 83