English
Language : 

MC3630 Datasheet, PDF (39/83 Pages) –
MC3630 3-Axis Accelerometer
Preliminary Datasheet
111
TRIG
Trigger mode, 1 to 254
samples or continuous, return
to sleep upon completion
3
NEW_DATA 0: No new sample data has arrived since last read.
1: New sample data has arrived and has been written to
FIFO/registers. This bit is always enabled and valid, regardless
of the settings of any interrupt enable bits.
4
FIFO_EMPTY 0: FIFO has one or more samples in storage (level)
1: FIFO is empty (level) (default). This bit is set to 1 immediately
after device power-up or device reset.
5
FIFO_FULL
0: FIFO has space or 1 or more samples (up to 32) (level).
1: FIFO is full, all 32 samples are used (level).
6
FIFO_THRESH 0: Amount of data in FIFO is less than the threshold (level)
1: Amount of data in FIFO is equal to or greater than the
threshold (level)
7
INT_PEND
0: No interrupt flags are pending in register 0x09 (level)
1: One or more interrupt flags are pending in register 0x09
(logical OR) (level).
Table 16. Status Register 1 Settings
mCube Proprietary
© 2016 mCube Inc. All rights Reserved
APS-048-0047v1.2
39 / 83