Use the following steps to initialize the CN8223 for proper UTOPIA port operation:
1. Put RS8234 in the global reset: write 0x40000000 to CONFIG0.
2. Write RS8234âs CONFIG0 to appropriate values, but do not overwrite the
GLOBAL_RESET bit.
3. Put CN8223 in the reset mode: write 0x0080 to CONFIG_5.
4. Initialize CN8223, including UTOPIA interface if needed.
5. Release CN8223 reset: write 0x0000 to CONFIG_5.
6. Release RS8234 reset: set GLOBAL_RESET bit to 0.
7. Enable RS8234âs Reassembly coprocessor.
8. Enable CN8223âs Receiver: write 0x0C02 to CELL_VAL register.
9. Enable RS8234âs Segmentation coprocessor.
0x2CâUTOPIA_2 (Utopia Port Control Register 2)
The UTOPIA_2 register is located at address 0x2C and controls operation of the UTOPIA interface.
Bit
Field
Size
Name
15â6 10
5â0
6
Reserved
Reserved
Set to 0.
Set to 35 hex.
Description