FLEX 10KE Embedded Programmable Logic Devices Data Sheet
Column-to-IOE Connections
When an IOE is used as an input, it can drive up to two separate column
channels. When an IOE is used as an output, the signal is driven by a
multiplexer that selects a signal from the column channels. Two IOEs
connect to each side of the column channels. Each IOE can be driven by
column channels via a multiplexer. The set of column channels is different
for each IOE (see Figure 17).
Figure 17. FLEX 10KE Column-to-IOE Connections
The values for m and n are provided in Table 11.
Each IOE is driven by
a m-to-1 multiplexer
m
IOE1
Column
n
Interconnect
n
n
m
IOE1
Each IOE can drive two
column channels.
Table 11 lists the FLEX 10KE column-to-IOE interconnect resources.
Table 11. FLEX 10KE Column-to-IOE Interconnect Resources
Device
EPF10K30E
EPF10K50E
EPF10K50S
EPF10K100E
EPF10K130E
EPF10K200E
EPF10K200S
Channels per Column (n) Column Channels per Pin (m)
24
16
24
16
24
16
32
24
48
40
36