Z8F082ASJ020EG Datasheet, PDF (94/282 Pages) Zilog, Inc. – High-Performance 8-Bit Microcontrollers
Z8 Encore! XP® F082A Series
Product Specification
77
The PWM period is represented by the following equation:
PWM Period (s) = -------R----e---l-o---a----d----V----a---l-u---e--------P----r--e---s--c---a---l-e--------
System Clock Frequency (Hz)
If an initial starting value other than 0001H is loaded into the Timer High and Low Byte
registers, use the ONE-SHOT Mode equation to determine the first PWM time-out period.
If TPOL is set to 0, the ratio of the PWM output High time to the total period is repre-
sented by:
PWM Output High Time Ratio (%) = R----e---l--o---a---d----V----a---l-u---e-----–---P----W-----M------V----a---l-u---e-  100
Reload Value
If TPOL is set to 1, the ratio of the PWM output High time to the total period is repre-
sented by:
PWM Output High Time Ratio (%) = --P----W-----M------V----a---l-u---e----  100
Reload Value
PWM DUAL OUTPUT Mode
In PWM DUAL OUTPUT Mode, the timer outputs a Pulse-Width Modulated (PWM) out-
put signal pair (basic PWM signal and its complement) through two GPIO port pins. The
timer input is the system clock. The timer first counts up to the 16-bit PWM match value
stored in the Timer PWM High and Low Byte registers. When the timer count value
matches the PWM value, the Timer Output toggles. The timer continues counting until it
reaches the reload value stored in the Timer Reload High and Low Byte registers. Upon
reaching the reload value, the timer generates an interrupt, the count value in the Timer
High and Low Byte registers is reset to 0001H and counting resumes.
If the TPOL bit in the Timer Control Register is set to 1, the Timer Output signal begins as
a High (1) and transitions to a Low (0) when the timer value matches the PWM value. The
Timer Output signal returns to a High (1) after the timer reaches the reload value and is
reset to 0001H.
If the TPOL bit in the Timer Control Register is set to 0, the Timer Output signal begins as
a Low (0) and transitions to a High (1) when the timer value matches the PWM value. The
Timer Output signal returns to a Low (0) after the timer reaches the reload value and is
reset to 0001H.
The timer also generates a second PWM output signal Timer Output Complement. The
Timer Output Complement is the complement of the Timer Output PWM signal. A pro-
grammable deadband delay can be configured to time delay (0 to 128 system clock cycles)
PWM output transitions on these two pins from a low to a high (inactive to active). This
PS022827-1212
PRELIMINARY
Operation