English
Language : 

DS541 Datasheet, PDF (20/27 Pages) Xilinx, Inc – Defense Grade Platform Flash In-System Programmable Configuration PROM
—PRODUCT OBSOLETE / UNDER OBSOLESCENCE—
Defense Grade Platform Flash In-System Programmable Configuration PROM
Table 14: XQF32P PROM as Configuration Master with Internal Oscillator as Clock Source
Symbol
Description
XQF32P
Min
Max
THCF
CF hold time to guarantee design revision selection is sampled
when VCCO = 3.3V or 2.5V(12)
300
–
CF hold time to guarantee design revision selection is sampled
when VCCO = 1.8V(12)
300
–
TCF
CF to data delay when VCCO = 3.3V or 2.5V
–
25
CF to data delay when VCCO = 1.8V
–
25
TOE
OE/RESET to data delay(6) when VCCO = 3.3V or 2.5V
OE/RESET to data delay(6) when VCCO = 1.8V
–
30
–
30
TCE
CE to data delay(5) when VCCO = 3.3V or 2.5V
CE to data delay(5) when VCCO = 1.8V
–
30
–
30
TEOH Data hold from CE, OE/RESET, or CF when VCCO = 3.3V or 2.5V
5
–
Data hold from CE, OE/RESET, or CF when VCCO = 1.8V
5
–
TDF
CE or OE/RESET to data float delay(2) when VCCO = 3.3V or 2.5V
–
45
CE or OE/RESET to data float delay(2) when VCCO = 1.8V
–
45
THCE CE hold time (guarantees counters are reset)(5) when VCCO = 3.3V or 2.5V
2000
–
CE hold time (guarantees counters are reset)(5) when VCCO = 1.8V
2000
–
THOE OE/RESET hold time (guarantees counters are reset)(6) when VCCO = 3.3V or 2.5V
2000
–
OE/RESET hold time (guarantees counters are reset)(6) when VCCO = 1.8V
2000
–
TSB
BUSY setup time to CLKOUT when VCCO = 3.3V or 2.5V
12
–
BUSY setup time to CLKOUT when VCCO = 1.8V
12
–
THB
BUSY hold time to CLKOUT when VCCO = 3.3V or 2.5V
8
–
BUSY hold time to CLKOUT when VCCO = 1.8V
8
–
TCEC CE to CLKOUT delay(7) when VCCO = 3.3V or 2.5V
0
1
CE to CLKOUT delay(7) when VCCO = 1.8V
0
1
TOEC
OE/RESET to CLKOUT delay(7) when VCCO = 3.3V or 2.5V
OE/RESET to CLKOUT delay(7) when VCCO = 1.8V
0
1
0
1
TCFC
CF to CLKOUT delay(7) when VCCO = 3.3V or 2.5V
CF to CLKOUT delay(7) when VCCO = 1.8V
0
–
0
–
TCDD
CLKOUT to data delay when VCCO = 3.3V or 2.5V(8)
CLKOUT to data delay when VCCO = 1.8V(8)
–
30
–
30
TDDC Data setup time to CLKOUT when VCCO = 3.3V or 2.5V with decompression (8)(11)
5
–
Data setup time to CLKOUT when VCCO = 1.8V with decompression(8)(11)
5
–
TCOH Data hold from CLKOUT when VCCO = 3.3V or 2.5V
3
–
Data hold from CLKOUT when VCCO = 1.8V
Data hold from CLKOUT when VCCO = 3.3V or 2.5V with decompression(11)
3
–
3
–
Data hold from CLKOUT when VCCO = 1.8V with decompression(11)
3
–
TSXT EN_EXT_SEL setup time to CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
300
–
EN_EXT_SEL setup time to CF, CE, or OE/RESET when VCCO = 1.8V
300
–
THXT EN_EXT_SEL hold time from CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
300
–
EN_EXT_SEL hold time from CF, CE, or OE/RESET when VCCO = 1.8V
300
–
DS541 (v3.0) August 5, 2015
Product Specification
www.xilinx.com
Send Feedback
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
µs
µs
µs
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
20