LogiCORE IP XPS SYSMON ADC (v3.00.b)
Table 11: IP Interrupt Status Register (IPISR) Description (C_BASEADDR + 0x60)
Bit(s) Name
Access
Reset
Value
Description
0 - 21 Undefined
N/A
N/A Undefined.
22
ALM[0]
Deactive
R/TOW(1)
ALM[0] Deactive Interrupt. This signal indicates that the falling edge of the
ALM[0] (ALM[0] indicates the user temperature range violation) signal is
â0â
detected. It is cleared by writing â1â to this bit position.
Note that the "ALM[0] Deactive" signal is generated locally from the core.
This signal indicates that the SYSMON macro has deactivated the user
temperature violation signal output.
23
OT
Deactive
R/TOW(1)
OT Deactive Interrupt. This signal indicates that the falling edge of the Over
Temperature signal is detected. It is cleared by writing â1â to this bit position.
â0â Note that the "OT Deactive" signal is generated locally from the core. This
signal indicates that the SYSMON macro has deactivated the Over
Temperature signal output.
24
JTAG
MODIFIED
R/TOW(1)(2)
â0â
JTAGMODIFIED Interrupt. This signal indicates that a write to DRP through
JTAG interface has occurred. It is cleared by writing â1â to this bit position.
25
JTAG
LOCKED
R/TOW(1)(2)
â0â
JTAGLOCKED Interrupt. This signal is used to indicate that a DRP port lock
request has been made by the Joint Test Action Group (JTAG) interface.
End of Conversion signal Interrupt. This signal transitions to an active High
26
EOC
R/TOW(1)(2)
N/A at the end of an ADC conversion when the measurement is written to the
SYSMON hard macroâs status register.
End of Sequence Interrupt. This signal transitions to an active High when
27
EOS
R/TOW(1)(2)
N/A the measurement data from the last channel in the auto sequence is written
to the status registers.
System Monitor VCCAUX-sensor Interrupt. System Monitor
28
ALM[2]
R/TOW(1)(2)
â0â VCCAUX-sensor alarm output interrupt occurs when VCCAUX exceeds
user defined threshold.
System Monitor VCCINT-sensor Interrupt. System Monitor VCCINT-sensor
29
ALM[1]
R/TOW(1)(2)
â0â alarm output interrupt occurs when VCCINT exceeds user defined
threshold.
System Monitor temperature-sensor Interrupt. System Monitor
30
ALM[0]
R/TOW(1)(2)
â0â temperature-sensor alarm output interrupt occurs when device temperature
exceeds user defined threshold.
Over-Temperature alarm Interrupt. Over-Temperature alarm output
31
OT
R/TOW(1)(2)
â0â interrupt occurs when the die temperature exceeds a factory set limit of 125
degree celsius.
Notes:
1. TOW = Toggle On Write. Writing a â1â to a bit position within the register causes the corresponding bit position in the register to
toggle.
2. This interrupt signal is directly generated from the SYSMON hard macro.
DS620 October 19, 2011
www.xilinx.com
18