English
Language : 

DS620 Datasheet, PDF (11/30 Pages) Dallas Semiconductor – Low-Voltage, +-0.5°C Accuracy Digital Thermometer and Thermostat
LogiCORE IP XPS SYSMON ADC (v3.00.b)
Table 4: Core Registers (Cont’d)
Base Address + Offset
(hex)
Register Name
C_BASEADDR + 0x260
VAUXP[8]/
VAUXN[8]
C_BASEADDR + 0x264
VAUXP[9]/
VAUXN[9]
C_BASEADDR + 0x268
VAUXP[10]/
VAUXN[10]
C_BASEADDR + 0x26C
VAUXP[11]/
VAUXN[11]
C_BASEADDR + 0x270
VAUXP[12]/
VAUXN[12]
C_BASEADDR + 0x274
VAUXP[13]/
VAUXN[13]
C_BASEADDR + 0x278
VAUXP[14]/
VAUXN[14]
C_BASEADDR + 0x27C
VAUXP[15]/
VAUXN[15]
C_BASEADDR + 0x280 Max Temp
C_BASEADDR + 0x284 Max VCCINT
C_BASEADDR + 0x288 Max VCCAUX
C_BASEADDR + 0x28C Undefined
C_BASEADDR + 0x290 Min Temp
C_BASEADDR + 0x294 Min VCCINT
C_BASEADDR + 0x298 Min VCCAUX
C_BASEADDR + 0x29C to
C_BASEADDR + 0x2F8
Undefined
C_BASEADDR + 0x2FC Flag Register
C_BASEADDR + 0x300
Configuration
Register 0
Access Type
Default
Value (hex)
Description
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 8
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 9
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 10
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 11
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 12
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 13
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 14
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 15
is stored in this register.
Read(6)
N/A
The 10-bit MSB justified maximum
temperature measurement.
Read(6)
N/A
The 10-bit MSB justified maximum VCCINT
measurement.
Read(6)
N/A
The 10-bit MSB justified maximum VCCAUX
measurement.
N/A
Undefined
This location is unused and contains
invalid data.
Read(6)
N/A
The 10-bit MSB justified minimum
temperature measurement.
Read(6)
N/A
The 10-bit MSB justified minimum VCCINT
measurement.
Read(6)
N/A
The 10-bit MSB justified minimum VCCAUX
measurement.
N/A
Undefined
These locations are unused and contain
invalid data.
Read(6)
The 16-bit register gives general status
information of ALARM, Over Temperature
N/A
(OT), Disable information of SYSMON and
information whether the SYSMON is using
internal reference voltage or external
reference voltage.
R/W(9)
0x0
SYSMON Configuration register 0
DS620 October 19, 2011
www.xilinx.com
11
Product Specification