LogiCORE IP XPS SYSMON ADC (v3.00.b)
Table 4: Core Registers (Cont’d)
Base Address + Offset
(hex)
Register Name
C_BASEADDR + 0x20C VP/VN
C_BASEADDR + 0x210 VREFP
C_BASEADDR + 0x214 VREFN
C_BASEADDR + 0x218 to
C_BASEADDR + 0x21C
Undefined
C_BASEADDR + 0x220 Supply Offset
C_BASEADDR + 0x224 ADC Offset
C_BASEADDR + 0x228 Gain Error
C_BASEADDR + 0x22C to
C_BASEADDR + 0x23C
Undefined
C_BASEADDR + 0x240
VAUXP[0]/
VAUXN[0]
C_BASEADDR + 0x244
VAUXP[1]/
VAUXN[1]
C_BASEADDR + 0x248
VAUXP[2]/
VAUXN[2]
C_BASEADDR + 0x24C
VAUXP[3]/
VAUXN[3]
C_BASEADDR + 0x250
VAUXP[4]/
VAUXN[4]
C_BASEADDR + 0x254
VAUXP[5]/
VAUXN[5]
C_BASEADDR + 0x258
VAUXP[6]/
VAUXN[6]
C_BASEADDR + 0x25C
VAUXP[7]/
VAUXN[7]
Access Type
Default
Value (hex)
Description
R/W(7)
When read: The 10-bit MSB justified result
of Analog-to-Digital (A/D) conversion on
the dedicated analog input channel
(Vp/Vn) is stored in this register
0x0
When written: Write to this register resets
the SYSMON hard macro. No specific data
is required. Applicable only when the
Virtex-6 device is targeted.
Read
The 10-bit MSB justified result of A/D
0x0
conversion on the reference input VREFP is
stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the reference input VREFN is
stored in this register.
N/A
Undefined
These locations are unused and contain
invalid data.
Read(6)
N/A
The calibration coefficient for the supply
sensor offset is stored in this register.
Read(6)
N/A
The calibration coefficient for the ADC
offset calibration is stored in this register.
Read(6)
N/A
The calibration coefficient for the gain error
is stored in this register.
N/A
Undefined
These locations are unused and contain
invalid data
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 0
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 1
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 2
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 3
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 4
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 5
is stored in this register
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 6
is stored in this register.
Read(6)
The 10-bit MSB justified result of A/D
0x0
conversion on the auxiliary analog input 7
is stored in this register.
DS620 October 19, 2011
www.xilinx.com
10