English
Language : 

W83627EHF Datasheet, PDF (94/141 Pages) Winbond – evolving product from Winbonds most popular I/O family
W83627EHF/EF, W83627EHG/EG
Bit 3: 3VCC Voltage status. Read 1, the voltage of 3VCC is over/under the limit value. Read 0, the
voltage of 3VCC is in the limit range.
Bit 2: AVCC Voltage status. Set 1, the voltage of AVCC is over/under the limit value. Read 0, the
voltage of AVCC is in the limit range.
Bit 1: VIN0 Voltage status. Set 1, the voltage of VIN0 is over/under the limit value. Read 0, the voltage
of VIN0 is in the limit range.
Bit 0: CPUVCORE Voltage status. Read 1, the voltage of CPUVCORE is over/under the limit value.
Read 0, the voltage of CPUVCORE is in the limit range.
6.8.90 Real Time Hardware Status Register II - Index 5Ah (Bank 4)
Register Location:
5Ah
Power on Default Value:
00h
Attribute:
Read Only
Size:
8 bits
7 6 5 4 32 1 0
VIN1_STS
TAR4_STS
CPUFANIN1_STS
AUXFANIN0_STS
CASEOPEN_STS
AUXTIN_STS
TAR1_STS
TAR2_STS
Bit 7: Smart Fan of CPUFANIN0 warning status. Read 1, the CPUTIN temperature has been over the
target temperature for 3 minutes with full fan speed at thermal cruise mode of SmartFanTM.
Read 0, the temperature does not reach the warning range yet.
Bit 6: Smart Fan of SYSFANIN warning status. Read 1, the SYSTIN temperature has been over the
target temperature for 3 minutes with full fan speed at thermal cruise mode of SmartFanTM.
Read 0, the temperature does not reach the warning range yet.
Bit 5: AUXTIN temperature sensor status. Read 1, the temperature exceeds the over-temperature limit
value. Read 0, the temperature is in under the hysteresis value.
Bit 4: Case Open status. Read 1, the case open is detected and latched. Read 0, the case is not
latched open.
Bit 3: AUXFANIN0 status. Read 1, the fan speed count is over the limit value. Read 0, the fan speed
count is in the limit range.
Bit 2: CPUFANIN1 status. Read 1, the fan speed count is over the limit value. Read 0, the fan speed
count is in the limit range.
Bit 1: Smart Fan of CPUFANIN1 warning status. Read 1, the select temperature has been over the
target temperature for 3 minutes with full fan speed at thermal cruise mode of SmartFanTM.
Read 0, the temperature does not reach the warning range yet.
Bit 0: VIN1 Voltage status. Read 1, the voltage of VIN1 is over/under the limit value. Read 0, the
voltage of VIN1 is in the limit range.
-88-