6.8.26 AUXFANOUT Stop Time Register - Index 17h (Bank 0)
Register Location:
17h
Power on Default Value:
3Ch
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
AUXFANOUT Stop Time
When at Thermal Cruise mode, this register determines the time of which AUXFANOUT value is from
stop value to 0.
(1)When at PWM output:
The unit of this register is 0.1 second. The default time is 6 seconds.
(2)When at DC Voltage output:
The unit of this register is 0.4 second. The default time is 24 seconds.
6.8.27 OVT# Configuration Register - Index 18h (Bank 0)
Register Location:
18h
Power on Default Value:
43h
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
Reserved
Reserved
Reserved
Reserved
OVT1_Mode
Reserved
DIS_OVT1
Reserved
Bit 7: Reserved.
Bit 6: Set to 1, disable temperature sensor SYSTIN over-temperature (OVT#) output. Set to 0, enable
the SYSTIN OVT# output.
Bit 5: Reserved.
Publication Release Date: January 18, 2006