English
Language : 

W83627EHF Datasheet, PDF (137/141 Pages) Winbond – evolving product from Winbonds most popular I/O family
W83627EHF/EF, W83627EHG/EG
8.3.2 AC Power Failure Resume Timing
1. CRE4 bit7 = “0” and CRE4 bit[6:5] are selected to “OFF” state
(“OFF” means always turn off or last state is off)
VCC
PSOUT#
PSON#
SUSB#
RSMRST#
VSB
ACLOSS
2. CRE4 bit7 = “0” and CRE4 bit[6:5] are selected to “ON” state
(“ON” means always turn on or last state is on)
VCC
PSOUT#
PSON#
SUSB#
RSMRST#
VSB
ACLOSS
-131-
Publication Release Date: January 18, 2006
Revision 1.0