W83627EHF Datasheet, PDF (62/141 Pages) Winbond – evolving product from Winbonds most popular I/O family
W83627EHF/EF, W83627EHG/EG
Bit 7-0: AUXFANOUT PWM Duty Cycle. Write FFh, AUXFANOUT duty cycle is 100%. Write 00h,
AUXFANOUT duty cycle is 0%.
Note. XXh: PWM Duty Cycle output percentage is (XX/256*100%) during one cycle.
(2)If AUXFANOUT be programmed as DC Voltage output (Bank0 Index 12h.bit0 is 1)
Bit 7-2: AUXFANOUT voltage control.
Bit 1-0: Reserved.
OUTPUT Voltage =
AVCC
*
FANOUT
16
Note. See the Table 6.4
6.8.21 FAN Configuration Register II - Index 12h (Bank 0)
Register Location:
12h
Power on Default Value:
00h
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
AUXFANOUT_SEL
AUXFANOUT_Mode
AUXFANOUT_Mode
AUXFANOUT_MIN_Value
CPUFANOUT0_MIN_Value
SYSFANOUT_MIN_Value
CPUFANOUT1_MIN_Value
Reserved
Bit 7: Reserved
Bit 6: Set 1, CPUFANOUT1 value will decrease to and keep the value set in Index 64h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, CPUFANOUT1 value will decrease to 0 when temperature goes below target range.
Bit 5: Set 1, SYSFANOUT value will decrease to and keep the value set in Index 08h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, SYSFANOUT value will decrease to 0 when temperature goes below target range.
Bit 4: Set 1, CPUFANOUT0 value will decrease to and keep the value set in Index 09h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, CPUFANOUT0 value will decrease to 0 when temperature goes below target range.
Bit 3: Set 1, AUXFANOUT value will decrease to and keep the value set in Index 17h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, AUXFANOUT value will decrease to 0 when temperature goes below target range.
Bit 2-1: AUXFANOUT mode control.
Set 00, AUXFANOUT is as Manual Mode. (Default).
-56-