English
Language : 

W83627EHF Datasheet, PDF (47/141 Pages) Winbond – evolving product from Winbonds most popular I/O family
W83627EHF/EF, W83627EHG/EG
TOI
THYST
SMI#
*
*
*Interrupt Reset when Interrupt Status Registers are read
Figure 6.16
6.6.3.2. Temperature sensor 2(CPUTIN) and sensor 3(AUXTIN) SMI# interrupt has two modes
It is programmed at Bank0 Index 4Ch.bit 6.
(1) Comparator Interrupt Mode
Temperature exceeding TO causes an interrupt and this interrupt will be reset by reading all the
Interrupt Status Register. Once an interrupt event has occurred by exceeding TO, then reset, if the
temperature remains above the THYST, the interrupt will occur again when the next conversion has
completed. If an interrupt event has occurred by exceeding TO and not reset, the interrupts will
not occur again. The interrupts will continue to occur in this manner until the temperature goes
below THYST. ( Figure 6.17 )
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status
Register. Once an interrupt event has occurred by exceeding TO , then reset, if the temperature
remains above the THYST , the interrupt will not occur. (Figure 6.18 )
TOI
THYST
SMI#
TOI
THYST
*
*
*
*
SMI#
*
*
*
*
Figure 6.17
*Interrupt Reset when Interrupt Status Registers are read
Figure 6.18
Publication Release Date: January 18, 2006
-41-
Revision 1.0