English
Language : 

LM3S2776 Datasheet, PDF (703/785 Pages) Texas Instruments – Stellaris® LM3S2776 Microcontroller
Stellaris® LM3S2776 Microcontroller
Bit/Field
0
Name
FAULT0
Type
R/W
Reset
0
Description
Fault0
Specifies the contribution of the FAULT0 input to the generation of a
fault condition.
Value Description
0 Suppressed
The FAULT0 signal is suppressed and cannot generate a fault
condition.
1 Generated
The FAULT0 signal value is ORed with all other fault condition
generation inputs (Fault signals).
November 17, 2011
703
Texas Instruments-Production Data