English
Language : 

TIC10024-Q1 Datasheet, PDF (69/81 Pages) Texas Instruments – 24-Input Multiple Switch Detection Interface (MSDI) Device With Adjustable Wetting Current for Automotive Systems
www.ti.com
Systems Examples (continued)
VBAT
VBAT, max
TIC10024-Q1
SCPS268 – SEPTEMBER 2017
VBAT, min
tr
t1
tf
t
Figure 44. Voltage Profile to Test a Jump Start Event
Table 25. Voltage Profile Parameters to Test a Jump Start Event
Parameter
Value
VBAT, min
10.8 V
VBAT, max
24 V
tr
< 10 ms
t1
60 s ± 6 s
tf
< 10 ms
Number of cycles
1
spacer
• To emulate a load dump event for an alternator with centralized load dump suppression, voltage profile
described in Figure 45 is used. UA and US* are applied directly to VBAT.
Figure 45. Voltage Profile to Test a Load Dump Event With Centralized Load Dump Suppression
Copyright © 2017, Texas Instruments Incorporated
Product Folder Links: TIC10024-Q1
Submit Documentation Feedback
69