9.4.15 INT_EN_COMP2 Register (Offset = 23h) [reset = 0h]
INT_EN_COMP2 is shown in Figure 39 and described in Table 21.
Return to Summary Table.
Figure 39. INT_EN_COMP2 Register
23
22
21
20
INC_EN_23
INC_EN_22
R/W-0h
R/W-0h
11
10
9
8
INC_EN_17
INC_EN_16
R/W-0h
R/W-0h
LEGEND: R/W = Read/Write
19
18
INC_EN_21
R/W-0h
7
6
INC_EN_15
R/W-0h
17
16
INC_EN_20
R/W-0h
5
4
INC_EN_14
R/W-0h
15
14
INC_EN_19
R/W-0h
3
2
INC_EN_13
R/W-0h
13
12
INC_EN_18
R/W-0h
1
0
INC_EN_12
R/W-0h
Table 21. INT_EN_COMP2 Register Field Descriptions
Bit
23-22
Field
INC_EN_23
21-20 INC_EN_22
19-18 INC_EN_21
17-16 INC_EN_20
15-14 INC_EN_19
Type
R/W
R/W
R/W
R/W
R/W
Reset
0h
0h
0h
0h
0h
Description
0h = no interrupt generation for IN23
1h = interrupt generation on rising edge above
THRES_COMP_IN20_IN23 for IN23
2h = interrupt generation on falling edge below
THRES_COMP_IN20_IN23 for IN23
3h = interrupt generation on falling and rising edge of
THRES_COMP_IN20_IN23 for IN23
0h = no interrupt generation for IN22
1h = interrupt generation on rising edge above
THRES_COMP_IN20_IN23 for IN22
2h = interrupt generation on falling edge below
THRES_COMP_IN20_IN23 for IN22
3h = interrupt generation on falling and rising edge of
THRES_COMP_IN20_IN23 for IN22
0h = no interrupt generation for IN21
1h = interrupt generation on rising edge above
THRES_COMP_IN20_IN23 for IN21
2h = interrupt generation on falling edge below
THRES_COMP_IN20_IN23 for IN21
3h = interrupt generation on falling and rising edge of
THRES_COMP_IN20_IN23 for IN21
0h = no interrupt generation for IN20
1h = interrupt generation on rising edge above
THRES_COMP_IN20_IN23 for IN20
2h = interrupt generation on falling edge below
THRES_COMP_IN20_IN23 for IN20
3h = interrupt generation on falling and rising edge of
THRES_COMP_IN20_IN23 for IN20
0h = no interrupt generation for IN19
1h = interrupt generation on rising edge above
THRES_COMP_IN16_IN19 for IN19
2h = interrupt generation on falling edge below
THRES_COMP_IN16_IN19 for IN19
3h = interrupt generation on falling and rising edge of
THRES_COMP_IN16_IN19 for IN19