English
Language : 

MSP430F677X1_16 Datasheet, PDF (68/162 Pages) Texas Instruments – Polyphase Metering SoCs
MSP430F677x1, MSP430F676x1, MSP430F674x1
SLAS815C – NOVEMBER 2012 – REVISED DECEMBER 2013
www.ti.com
Internal Very-Low-Power Low-Frequency Oscillator (VLO)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
fVLO
VLO frequency
dfVLO/dT VLO frequency temperature drift
dfVLO/dVCC VLO frequency supply voltage drift
Duty cycle
TEST CONDITIONS
Measured at ACLK
Measured at ACLK
Measured at ACLK
Measured at ACLK
VCC
1.8 V to 3.6 V
1.8 V to 3.6 V
1.8 V to 3.6 V
1.8 V to 3.6 V
MIN TYP
6 9.6
0.5
4
40
50
MAX
15
60
UNIT
kHz
%/°C
%/V
%
Internal Reference, Low-Frequency Oscillator (REFO)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
IREFO
PARAMETER
REFO oscillator current consumption
REFO frequency calibrated
TEST CONDITIONS
TA = 25°C
Measured at ACLK
VCC
1.8 V to 3.6 V
1.8 V to 3.6 V
MIN TYP
3
32768
fREFO
dfREFO/dT
dfREFO/dVCC
REFO absolute tolerance calibrated
REFO frequency temperature drift
REFO frequency supply voltage drift
Duty cycle
Full temperature range
TA = 25°C
Measured at ACLK
Measured at ACLK
Measured at ACLK
1.8 V to 3.6 V
3V
1.8 V to 3.6 V
1.8 V to 3.6 V
1.8 V to 3.6 V
-3.5
-1.5
0.01
1.0
40
50
tSTART
REFO startup time
40%/60% duty cycle
1.8 V to 3.6 V
25
MAX
+3.5
+1.5
60
UNIT
µA
Hz
%
%
%/°C
%/V
%
µs
DCO Frequency
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
fDCO(0,0)
fDCO(0,31)
fDCO(1,0)
fDCO(1,31)
fDCO(2,0)
fDCO(2,31)
fDCO(3,0)
fDCO(3,31)
fDCO(4,0)
fDCO(4,31)
fDCO(5,0)
fDCO(5,31)
fDCO(6,0)
fDCO(6,31)
fDCO(7,0)
fDCO(7,31)
SDCORSEL
PARAMETER
DCO frequency (0, 0)(1)
DCO frequency (0, 31)(1)
DCO frequency (1, 0)(1)
DCO frequency (1, 31)(1)
DCO frequency (2, 0)(1)
DCO frequency (2, 31)(1)
DCO frequency (3, 0)(1)
DCO frequency (3, 31)(1)
DCO frequency (4, 0)(1)
DCO frequency (4, 31)(1)
DCO frequency (5, 0)(1)
DCO frequency (5, 31)(1)
DCO frequency (6, 0)(1)
DCO frequency (6, 31)(1)
DCO frequency (7, 0)(1)
DCO frequency (7, 31)(1)
Frequency step between range
DCORSEL and DCORSEL + 1
TEST CONDITIONS
DCORSELx = 0, DCOx = 0, MODx = 0
DCORSELx = 0, DCOx = 31, MODx = 0
DCORSELx = 1, DCOx = 0, MODx = 0
DCORSELx = 1, DCOx = 31, MODx = 0
DCORSELx = 2, DCOx = 0, MODx = 0
DCORSELx = 2, DCOx = 31, MODx = 0
DCORSELx = 3, DCOx = 0, MODx = 0
DCORSELx = 3, DCOx = 31, MODx = 0
DCORSELx = 4, DCOx = 0, MODx = 0
DCORSELx = 4, DCOx = 31, MODx = 0
DCORSELx = 5, DCOx = 0, MODx = 0
DCORSELx = 5, DCOx = 31, MODx = 0
DCORSELx = 6, DCOx = 0, MODx = 0
DCORSELx = 6, DCOx = 31, MODx = 0
DCORSELx = 7, DCOx = 0, MODx = 0
DCORSELx = 7, DCOx = 31, MODx = 0
SRSEL = fDCO(DCORSEL+1,DCO)/fDCO(DCORSEL,DCO)
MIN TYP
0.07
0.70
0.15
1.47
0.32
3.17
0.64
6.07
1.3
12.3
2.5
23.7
4.6
39.0
8.5
60
1.2
SDCO
Frequency step between tap
DCO and DCO + 1
SDCO = fDCO(DCORSEL,DCO+1)/fDCO(DCORSEL,DCO)
1.02
Duty cycle
Measured at SMCLK
40
50
dfDCO/dT
DCO frequency temperature drift fDCO = 1 MHz
0.1
MAX
0.20
1.70
0.36
3.45
0.75
7.38
1.51
14.0
3.2
28.2
6.0
54.1
10.7
88.0
19.6
135
UNIT
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
2.3 ratio
1.12 ratio
60 %
%/°C
(1) When selecting the proper DCO frequency range (DCORSELx), the target DCO frequency, fDCO, should be set to reside within the
range of fDCO(n, 0),MAX ≤ fDCO ≤ fDCO(n, 31),MIN, where fDCO(n, 0),MAX represents the maximum frequency specified for the DCO frequency,
range n, tap 0 (DCOx = 0) and fDCO(n,31),MIN represents the minimum frequency specified for the DCO frequency, range n, tap
31 (DCOx = 31). This ensures that the target DCO frequency resides within the range selected. It should also be noted that if the actual
fDCO frequency for the selected range causes the FLL or the application to select tap 0 or 31, the DCO fault flag is set to report that the
selected range is at its minimum or maximum tap setting.
68
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated