English
Language : 

MSP430F677X1_16 Datasheet, PDF (63/162 Pages) Texas Instruments – Polyphase Metering SoCs
MSP430F677x1, MSP430F676x1, MSP430F674x1
www.ti.com
SLAS815C – NOVEMBER 2012 – REVISED DECEMBER 2013
Schmitt-Trigger Inputs – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VIT+ Positive-going input threshold voltage
TEST CONDITIONS
VCC
1.8 V
3V
MIN TYP
0.80
1.50
VIT– Negative-going input threshold voltage
1.8 V
0.45
3V
0.75
Vhys Input voltage hysteresis (VIT+ – VIT–)
1.8 V
0.3
3V
0.4
RPull
CI
Pullup or pulldown resistor(1)
Input capacitance
For pullup: VIN = VSS,
For pulldown: VIN = VCC
VIN = VSS or VCC
20
35
5
(1) Also applies to RST pin when pullup or pulldown resistor is enabled.
MAX
1.40
2.10
1.00
1.65
0.85
1.0
UNIT
V
V
V
50 kΩ
pF
Inputs – Ports P1 and P2(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
t(int)
External interrupt timing(2)
TEST CONDITIONS
VCC
MIN
Port P1, P2: P1.x to P2.x, External trigger pulse duration
to set interrupt flag
2.2 V, 3 V
20
MAX UNIT
ns
(1) Some devices may contain additional ports with interrupts. See the block diagram and terminal function descriptions.
(2) An external signal sets the interrupt flag every time the minimum interrupt pulse duration t(int) is met. It may be set by trigger signals
shorter than t(int).
Leakage Current – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
Ilkg(Px.y)
PARAMETER
High-impedance leakage current
TEST CONDITIONS
(1) (2)
VCC
1.8 V, 3 V
MIN MAX UNIT
-50 +50 nA
(1) The leakage current is measured with VSS or VCC applied to the corresponding pins, unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input and the pullup or pulldown resistor is
disabled.
Copyright © 2012–2013, Texas Instruments Incorporated
Submit Documentation Feedback
63