English
Language : 

MSP430F677X1_16 Datasheet, PDF (62/162 Pages) Texas Instruments – Polyphase Metering SoCs
MSP430F677x1, MSP430F676x1, MSP430F674x1
SLAS815C – NOVEMBER 2012 – REVISED DECEMBER 2013
www.ti.com
Low-Power Mode With LCD Supply Currents (Into VCC) Excluding External Current
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)(1)(2)
PARAMETER
Temperature (TA)
VCC
PMMCOREVx
-40°C
25°C
85°C
TYP MAX TYP MAX TYP MAX
0
2.5
ILPM3
Low-power mode 3 (LPM3)
1
2.6
LCD,
current, LCD 4-mux mode, 3 V
ext. bias
external biasing(3) (4)
2
2.8
3
2.8
3.1
9.1
3.3
9.5
3.5
9.9
3.5
6.0 10.0 25.0
0
2.9
ILPM3
LCD,
int. bias
Low-power mode 3 (LPM3)
current, LCD 4-mux mode,
internal biasing, charge
3V
pump disabled(3) (5)
1
2
3.1
3.2
3
3.3
3.5
9.7
3.7
10.1
4.0
10.5
4.0
5.5 10.5 25.0
0
2.2
2.8
8.8
2.2 V
1
2.3
3.0
9.1
Low-power mode 3 (LPM3)
2
2.5
ILPM3
LCD,CP
current, LCD 4-mux mode,
internal biasing, charge
0
2.6
pump enabled(3) (6)
1
2.8
3V
2
2.9
3.2
9.5
3.2
9.3
3.4
9.7
3.6
10.1
3
3.0
3.7
10.2
UNIT
µA
µA
µA
µA
(1) All inputs are tied to 0 V or to VCC. Outputs do not source or sink any current.
(2) The currents are characterized with a Micro Crystal MS1V-T1K crystal with a load capacitance of 12.5 pF. The internal and external load
capacitance are chosen to closely match the required 12.5 pF.
(3) Current for watchdog timer and RTC clocked by ACLK included. ACLK = low frequency crystal operation (XTS = 0, XT1DRIVEx = 0).
CPUOFF = 1, SCG0 = 1, SCG1 = 1, OSCOFF = 0 (LPM3); fACLK = 32768 Hz, fMCLK = fSMCLK = fDCO = 0 MHz
Current for brownout, high side supervisor (SVSH) normal mode included. Low side supervisor and monitors disabled (SVSL, SVML).
High side monitor disabled (SVMH). RAM retention enabled.
(4) LCDMx = 11 (4-mux mode), LCDREXT = 1, LCDEXTBIAS = 1 (external biasing), LCD2B = 0 (1/3 bias), LCDCPEN = 0 (charge pump
disabled), LCDSSEL = 0, LCDPREx = 101, LCDDIVx = 00011 (fLCD = 32768 Hz / 32 / 4 = 256 Hz)
Current through external resistors not included (voltage levels are supplied by test equipment).
Even segments S0,S2,... = 0, odd segments S1,S3,... = 1. No LCD panel load.
(5) LCDMx = 11 (4-mux mode), LCDREXT = 0, LCDEXTBIAS = 0 (internal biasing), LCD2B = 0 (1/3 bias), LCDCPEN = 0 (charge pump
disabled), LCDSSEL = 0, LCDPREx = 101, LCDDIVx = 00011 (fLCD = 32768 Hz / 32 / 4 = 256 Hz)
Even segments S0,S2,... = 0, odd segments S1,S3,... = 1. No LCD panel load.
(6) LCDMx = 11 (4-mux mode), LCDREXT = 0, LCDEXTBIAS = 0 (internal biasing), LCD2B = 0 (1/3 bias), LCDCPEN = 1 (charge pump
enabled), VLCDx = 1000 (VLCD = 3V,typ.), LCDSSEL = 0, LCDPREx = 101, LCDDIVx = 00011 (fLCD = 32768 Hz / 32 / 4 = 256 Hz)
Even segments S0,S2,... = 0, odd segments S1,S3,... = 1. No LCD panel load.
62
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated