English
Language : 

SM470R1B1M-HT Datasheet, PDF (60/67 Pages) Texas Instruments – 16/32-BIT RISC FLASH MICROCONTROLLER
SM470R1B1M-HT
SPNS155F – SEPTEMBER 2009 – REVISED AUGUST 2012
HIGH-END TIMER (HET) TIMINGS
www.ti.com
Minimum PWM Output Pulse Width:
This is equal to one high resolution clock period (HRP). The HRP is defined by the 6-bit high resolution prescale
factor (hr), which is user defined, giving prescale factors of 1 to 64, with a linear increment of codes.
Therefore, the minimum PWM output pulse width = HRP(min) = hr(min)/SYSCLK = 1/SYSCLK
For example, for a SYSCLK of 30 MHz, the minimum PWM output pulse width = 1/30 = 33.33ns
Minimum Input Pulses that Can Be Captured:
The input pulse width must be greater or equal to the low resolution clock period (LRP), i.e., the HET loop (the
HET program must fit within the LRP). The LRP is defined by the 3-bit loop-resolution prescale factor (lr), which
is user defined, with a power of 2 increment of codes. That is, the value of lr can be 1, 2, 4, 8, 16, or 32.
Therefore, the minimum input pulse width = LRP(min) = hr(min) * lr(min)/SYSCLK = 1 * 1/SYSCLK
For example, with a SYSCLK of 30 MHz, the minimum input pulse width = 1 * 1/30 = 33.33 ns
NOTE
Once the input pulse width is greater than LRP, the resolution of the measurement is still
HRP. (That is, the captured value gives the number of HRP clocks inside the pulse.)
Abbreviations:
hr = HET high resolution divide rate = 1, 2, 3,...63, 64
lr = HET low resolution divide rate = 1, 2, 4, 8, 16, 32
High resolution clock period = HRP = hr/SYSCLK
Loop resolution clock period = LRP = hr*lr/SYSCLK
60
Submit Documentation Feedback
Copyright © 2009–2012, Texas Instruments Incorporated