English
Language : 

MSP430F673X Datasheet, PDF (51/121 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
www.ti.com
MSP430F673x
MSP430F672x
SLAS731A – DECEMBER 2011 – REVISED APRIL 2012
Inputs – Ports P1 and P2(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
t(int)
External interrupt timing(2)
TEST CONDITIONS
VCC
MIN
Port P1, P2: P1.x to P2.x, External trigger pulse width to
set interrupt flag
2.2 V/3 V
20
MAX UNIT
ns
(1) Some devices may contain additional ports with interrupts. See the block diagram and terminal function descriptions.
(2) An external signal sets the interrupt flag every time the minimum interrupt pulse width t(int) is met. It may be set by trigger signals shorter
than t(int).
Leakage Current – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
Ilkg(Px.y)
PARAMETER
High-impedance leakage current
TEST CONDITIONS
See (1) (2)
VCC
MIN
1.8 V/3 V
MAX UNIT
±50 nA
(1) The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input and the pullup/pulldown resistor is
disabled.
Outputs – General Purpose I/O (Full Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VOH High-level output voltage
VOL Low-level output voltage
TEST CONDITIONS
I(OHmax) = –3 mA (1)
I(OHmax) = –10 mA(1)
I(OHmax) = –5 mA(1)
I(OHmax) = –15 mA(1)
I(OLmax) = 3 mA (2)
I(OLmax) = 10 mA (3)
I(OLmax) = 5 mA (2)
I(OLmax) = 15 mA(3)
VCC
1.8 V
3V
1.8 V
3V
MIN
VCC – 0.25
VCC – 0.60
VCC – 0.25
VCC – 0.60
VSS
VSS
VSS
VSS
MAX
VCC
VCC
VCC
VCC
VSS + 0.25
VSS + 0.60
VSS + 0.25
VSS + 0.60
UNIT
V
V
(1) The maximum total current, I(OHmax), for all outputs combined should not exceed ±20 mA to hold the maximum voltage drop specified.
See Recommended Operating Conditions for more details.
(2) The maximum total current, I(OLmax), for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop specified.
(3) The maximum total current, I(OLmax), for all outputs combined should not exceed ±100 mA to hold the maximum voltage drop specified.
Copyright © 2011–2012, Texas Instruments Incorporated
Submit Documentation Feedback
51