English
Language : 

LM3S300-IQN25-C2 Datasheet, PDF (473/498 Pages) Texas Instruments – Stellaris LM3S300 Microcontroller
NRND: Not recommended for new designs.
Stellaris® LM3S300 Microcontroller
A.4.4
A.4.5
A.4.6
Byte[8] = Program Size [23:16]
Byte[9] = Program Size [15:8]
Byte[10] = Program Size [7:0]
COMMAND_SEND_DATA (0x24)
This command should only follow a COMMAND_DOWNLOAD command or another
COMMAND_SEND_DATA command if more data is needed. Consecutive send data commands
automatically increment address and continue programming from the previous location. The caller
should limit transfers of data to a maximum 8 bytes of packet data to allow the flash to program
successfully and not overflow input buffers of the serial interfaces. The command terminates
programming once the number of bytes indicated by the COMMAND_DOWNLOAD command has been
received. Each time this function is called it should be followed by a COMMAND_GET_STATUS to
ensure that the data was successfully programmed into the flash. If the flash loader sends a NAK
to this command, the flash loader does not increment the current address to allow retransmission
of the previous data.
Byte[0] = 11
Byte[1] = checksum(Bytes[2:10])
Byte[2] = COMMAND_SEND_DATA
Byte[3] = Data[0]
Byte[4] = Data[1]
Byte[5] = Data[2]
Byte[6] = Data[3]
Byte[7] = Data[4]
Byte[8] = Data[5]
Byte[9] = Data[6]
Byte[10] = Data[7]
COMMAND_RUN (0x22)
This command is used to tell the flash loader to execute from the address passed as the parameter
in this command. This command consists of a single 32-bit value that is interpreted as the address
to execute. The 32-bit value is transmitted MSB first and the flash loader responds with an ACK
signal back to the host device before actually executing the code at the given address. This allows
the host to know that the command was received successfully and the code is now running.
Byte[0] = 7
Byte[1] = checksum(Bytes[2:6])
Byte[2] = COMMAND_RUN
Byte[3] = Execute Address[31:24]
Byte[4] = Execute Address[23:16]
Byte[5] = Execute Address[15:8]
Byte[6] = Execute Address[7:0]
COMMAND_RESET (0x25)
This command is used to tell the flash loader device to reset. This is useful when downloading a
new image that overwrote the flash loader and wants to start from a full reset. Unlike the
COMMAND_RUN command, this allows the initial stack pointer to be read by the hardware and set
up for the new code. It can also be used to reset the flash loader if a critical error occurs and the
host device wants to restart communication with the flash loader.
June 18, 2012
473