HD6433694 Datasheet, PDF (58/432 Pages) Renesas Technology Corp – 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Tiny Series | |||
|
◁ |
Table 2.8 System Control Instructions
Instruction Size* Function
TRAPA
â
Starts trap-instruction exception handling.
RTE
â
Returns from an exception-handling routine.
SLEEP
â
Causes a transition to a power-down state.
LDC
B/W (EAs) â CCR
Moves the source operand contents to the CCR. The CCR size is one
byte, but in transfer from memory, data is read by word access.
STC
B/W CCR â (EAd)
Transfers the CCR contents to a destination location. The condition code
register size is one byte, but in transfer to memory, data is written by
word access.
ANDC
B
CCR ⧠#IMM â CCR
Logically ANDs the CCR with immediate data.
ORC
B
CCR ⨠#IMM â CCR
Logically ORs the CCR with immediate data.
XORC
B
CCR â #IMM â CCR
Logically XORs the CCR with immediate data.
NOP
â
PC + 2 â PC
Only increments the program counter.
Note: * Refers to the operand size.
B: Byte
W: Word
Rev. 4.00, 03/04, page 30 of 400
|
▷ |