Start reception
[1] Read the OER flag in SSR to determine if
there is an error. If an overrun error has
Read OER flag in SSR
[1]
occurred, execute overrun error processing.
[2] Read SSR and check that the RDRF flag is
OER = 1
No
Yes
[4]
Error processing
set to 1, then read the receive data in RDR.
When data is read from RDR, the RDRF
flag is automatically cleared to 0.
[3] To continue serial reception, before the
MSB (bit 7) of the current frame is received,
(Continued below)
reading the RDRF flag and reading RDR
should be finished. When data is read from
Read RDRF flag in SSR
[2]
RDR, the RDRF flag is automatically
cleared to 0.
No
RDRF = 1
[4] If an overrun error occurs, read the OER
flag in SSR, and after performing the
appropriate error processing, clear the OER
Yes
flag to 0. Reception cannot be resumed if
the OER flag is set to 1.
Read receive data in RDR
Yes
All data received?
[3]
No
Clear RE bit in SCR3 to 0
<End>
[4]
Error processing
Overrun error processing
Clear OER flag in SSR to 0
<End>
Figure 14.13 Sample Serial Reception Flowchart (Clocked Synchronous Mode)