English
Language : 

MC68HC908RF2 Datasheet, PDF (211/254 Pages) Motorola, Inc – HCMOS Microcontroller Unit
Timer Interface Module (TIM)
I/O Registers
15.9.1 TIM Status and Control Register
The TIM status and control register (TSC):
• Enables TIM overflow interrupts
• Flags TIM overflows
• Stops the TIM counter
• Resets the TIM counter
• Prescales the TIM counter clock
Address: $0020
Bit 7
6
5
4
3
2
1
Bit 0
Read: TOF
0
0
TOIE TSTOP
Write: 0
TRST
PS2
PS1
PS0
Reset: 0
0
1
0
0
0
0
0
= Unimplemented
Figure 15-4. TIM Status and Control Register (TSC)
TOF — TIM Overflow Flag Bit
This read/write flag is set when the TIM counter resets to $0000 after
reaching the modulo value programmed in the TIM counter modulo
registers. Clear TOF by reading the TIM status and control register
when TOF is set and then writing a logic 0 to TOF. If another TIM
overflow occurs before the clearing sequence is complete, then
writing logic 0 to TOF has no effect. Therefore, a TOF interrupt
request cannot be lost due to inadvertent clearing of TOF. Reset
clears the TOF bit. Writing a logic 1 to TOF has no effect.
1 = TIM counter has reached modulo value.
0 = TIM counter has not reached modulo value.
TOIE — TIM Overflow Interrupt Enable Bit
This read/write bit enables TIM overflow interrupts when the TOF bit
becomes set. Reset clears the TOIE bit.
1 = TIM overflow interrupts enabled
0 = TIM overflow interrupts disabled
MC68HC908RF2 — Rev. 1
MOTOROLA
Timer Interface Module (TIM)
Advance Information
211