English
Language : 

409-10029 Datasheet, PDF (29/31 Pages) Tyco Electronics – When reading this manual, pay particular attention to DANGER, CAUTION, and NOTE statements.
Stripping Module 1490503-[ ] and 1490501-[ ]
409-10029
7. Adjust the height of the start sensor so that the lever is centered in the opening of the outer strip
blade.
8. Fully tighten two screws securing the start sensor assembly to the start sensor block.
9. Install the middle screw through the wire clamp and start sensor arm and into the start sensor block.
Fully tighten the middle screw.
10. Install the wire clamp onto the strip air cylinder with the new start sensor assembly wire passing
through the clamp.
NOTE
i
Be sure that a loop of wire exists between the wire clamp on the back of the strip air cylinder and the start sensor arm
when the arm is located all the way forward.
9.3. Recommended Spare Parts
S Start Sensor Assembly – 1424647–1
S Stripping Blades – Outer Blade –– 1424650–1; Inner Blade –– 1424649–1
10. REVISION SUMMARY
Since the previous release, the document format updated to current corporate requirements and the logo was
changed.
Rev C
Tyco Electronics Corporation
29 of 31