English
Language : 

409-10029 Datasheet, PDF (21/31 Pages) Tyco Electronics – When reading this manual, pay particular attention to DANGER, CAUTION, and NOTE statements.
Stripping Module 1490503-[ ] and 1490501-[ ]
409-10029
Flashes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Stripping Module Controller Error Codes
Error
(Error code not used)
Guard was opened.
Guard must be closed.
Switch did not “unmake” within the allotted time.
Switch did not “make” within the allotted time.
Faulty switch detected.
Tonk switch is faulty.
Did not sense tonk switch.
Tonk mechanism is stuck “down.”
Terminator is not at top–dead–center (TDC) position
Stripping unit Main Air is “off.”
Tooling is not in machine.
Wire sensor is bad or stuck in the “on” position.
Footswitch is bad or stuck in the “on” position.
(Error should not occur when stripping module is properly connected to terminating
machine)
Bad footswitch input detected.
Bad keypad detected.
Bad spare input detected.
Transfer mechanism is not shifted to the right.
Bad wire sensor input detected.
Figure 10
4.6. Stripping Module Removal
The stripping module may need to be removed when changing applicators (refer to Paragraph 4.2,C for
applicator installation procedures).
DANGER
To avoid personal injury, be sure to disconnect power to the terminating machine and the stripping module before
proceeding.
1. Loosen the cap screw located at the right side of the module.
2. “Back off” the clamp on the right side of the module.
3. Slide the module to the right and lift “up,” to removing the module from the mounting base.
Rev C
Tyco Electronics Corporation
21 of 31