English
Language : 

409-10029 Datasheet, PDF (20/31 Pages) Tyco Electronics – When reading this manual, pay particular attention to DANGER, CAUTION, and NOTE statements.
Stripping Module 1490503-[ ] and 1490501-[ ]
409-10029
Right-Side Installation
DANGER
To avoid personal injury, be sure to disconnect power to the terminating machine and stripping module before installing
or removing the applicator.
1. Remove the upper portion of the strip assembly by loosening the locking latch on the right side of the
transfer assembly.
2. Lift the strip assembly off the transfer assembly and set it on a work bench.
3. Remove the tonk rod from the ram post adapter.
4. Loosen the screw holding the scrap deflector and rotate the scrap deflector toward the front of the
machine.
5. Loosen the (applicator) latch on the machine base plate and push it down out of the way.
6. From the right side, place the applicator on the base plate.
7. Slide the applicator ram into the ram post of the terminating machine.
8. Place the left (applicator) latch on the terminator base plate into the slots on the (applicator) base
plate.
9. Lift the right (applicator) latch and tighten it against the applicator base plate.
10. Rotate the scrap deflector back against the applicator base and tighten the hold down screws.
11. Place the upper portion of strip assembly back on the transfer assembly.
12. Partially tighten the locking latch.
13. Push the upper portion of the strip assembly toward the rear of the machine until the wire brush
adjustment screw bottoms on the rear stop.
14. Install the tonk into the ram post adapter.
15. Manually cycle the terminating machine and stripping module to verify fit, clearance, and proper
operation.
4.3. Power On" Sequence
When AC power is first applied to the terminating machine and stripping module controller, all the LEDs on the
console will turn “on” and then immediately turn “off.” Then the necessary LEDs will turn “on” again, permitting
inspection of the LED conditions. The controller will then display any internal controller errors using the Error
LED. Refer to Paragraph 4.5. An error detected at this time will not be able to be reset. If no internal errors
were encountered:
a. the Power Off LED will turn “on;”
b. the LED for the current cycle start method will turn “on;” and
c. the LED indicating the last selected operating mode will also be turned “on.”
4.4. Condition After Power On" Sequence
After the “Power On” sequence has completed, the Power On LED, the LED for the current mode, and the
LED for the current cycle start method will turn “on.”
4.5. Stripping Module Errors (Error Reset Button and LED Code)
In addition to the Pullback, Transfer and Terminator errors described in Figure 6, the following errors will be
reported by the controller. The error will be displayed by flashing the Error LED the indicated number of times
indicated in Figure 10.
20 of 31
Tyco Electronics Corporation
Rev C