English
Language : 

409-10029 Datasheet, PDF (23/31 Pages) Tyco Electronics – When reading this manual, pay particular attention to DANGER, CAUTION, and NOTE statements.
Stripping Module 1490503-[ ] and 1490501-[ ]
409-10029
6. DIAGNOSTICS
6.1. Software Version Identification
1. Turn “off” power to the terminating machine and the stripping module.
2. Turn the system “on” and wait for the stripping module controller operator interface LEDs to be turned
on.
3. When the LEDs come on, press and hold the Single Step button (refer to Figure 6). The Single Step
LED will then flash the software version.
NOTE
Single Step The software version will be repeated as long as the
button is depressed.
i
The format for the software version is “X. Y. Z.” where:
S X represents the major software revision,
S Y represents the secondary software revision, and
S Z represents the minor software revision.
The “.” between each number is represented by a pause.
When the entire version is finished blinking, a one–second delay will be observed. Following the delay, the
software version will be repeated. Thus, a software version of “1.2.3” would be represented as:
– Flash
– (Short Pause)
– Flash, Flash
– (Short Pause)
– Flash, Flash, Flash
– One–second pause
Following the one–second pause, the process will repeat itself.
6.2. Input Monitoring Mode
To place the stripping module controller in the Input Monitoring Mode, proceed as follows:
1. Turn “off” power to the terminating machine and the stripping module.
2. Turn the system “on” and wait for the stripping module controller operator interface LEDs to be turned
“on.”
3. With all LEDs on, press and hold the Mode Select button (see Figure 6) for two seconds after all the
LEDs are turned “off.”
4. Release the Mode Select button and the Input monitoring function will be operative.
In this mode, the current state of the switches and inputs are displayed using the LEDs on the operator
interface. The LEDs correspond to the inputs as designated below (Figure 11).
LED
INPUT/SWITCH
Strip and Crimp mode LED
Crimp Only Mode LED
Strip Only Mode LED
Pullback Error LED
Transfer Error LED
Terminator Error LED
Error LED
(Not used with G" Terminator)
Tooling installed Switch
Guard interlock Switch
Pullback Switch
Side Transfer Switch
Terminator TDC Switch
Tonk Switch
Wire Sensor LED
Footswitch LED
Wire Sensor Input
Footswitch Input
Figure 11
Rev C
Tyco Electronics Corporation
23 of 31