409-10029 Datasheet, PDF (18/31 Pages) Tyco Electronics – When reading this manual, pay particular attention to DANGER, CAUTION, and NOTE statements.
Stripping Module 1490503-[ ] and 1490501-[ ]
409-10029
When lit, the LED above the Pullback Error Icon indicates that the gripping stripping tooling
has not completed the retracted or extended function of the operation. Observe the error
Error Reset LED code displayed by the
for additional information describing the error.
When lit, the LED above the Transfer Error Icon indicates that the gripping stripping tooling
Error Reset has failed to transfer to the right or left. Observe the error code displayed by the
LED for additional information describing the error.
When lit, the LED above the Terminator Error Icon indicates that the terminator has failed
Error Reset LED to complete its cycle. Observe the error code displayed by the
for additionĆ
al information describing the error.
The function of the Error Reset Button is to reset an existing stripping error. When an error
Error LED occurs, the
will blink a code that indicates the current error. (See Paragraph 4.4.)
The error code is repeated continuously until acknowledged and cleared by pressing the
Error Reset Button. If the error occurs in the Pullback, Transfer, or Terminator section, the
corresponding Error LED will also be illuminated.
Figure 9 (Sheet 2 of 3)
18 of 31
Tyco Electronics Corporation
Rev C