PSRAM READ OPERATIONS
Parameter
Symbol
Min Max.
Unit
Read Cycle Time
tRC
70
—
ns
Chip Enable Access Time(1,3)
tCE
—
65
ns
Output Enable Access Time(1)
tOE
—
40
ns
Address Access Time(1,4)
tAA
—
65
ns
Output Data Hold Time(1)
tOH
5
—
ns
CE1r Low to Output Low-Z(2)
tCLZ
5
—
ns
OE Low to Output Low-Z(2)
tOLZ
0
—
ns
CE1r High to Output High-Z(2)
tCHZ
—
20
ns
OE High to Output High-Z(2)
tOHZ
—
20
ns
Address Setup Time to CE1r Low(5)
tASC
-5
—
ns
Address Setup Time to OE(3,6)
tASO
25
—
ns
Address Setup Time to OE(7)
tASO(ABS)
10
—
ns
LB/UB Set up Time to CE1r Low(5)
tBSC
-5
—
ns
LB/UB Set up Time to OE Low
tBSO
-10
—
ns
Address Invalid Time(4)
tAX
—
5
ns
Address Hold Time from CE1r Low(4)
tCLAH
70
—
ns
Address Hold Time from OE Low(4,8)
tOLAH
45
—
ns
Address Hold Time from CE1r High
tCHAH
-5
—
ns
Address Hold Time from OE High
tOHAH
-5
—
ns
LB/UB Hold Time to CE1r Low
tCHBH
-5
—
ns
LB/UB Hold Time to OE Low
tOHBH
-5
—
ns
CE1r Low to OE Low Delay Time(3,6,8,9)
tCLOL
25
1000
ns
OE Low to CE1r High Delay Time(8)
tOLCH
45
—
ns
CE1r High Pulse Width
tCP
12
—
ns
OE High Pulse Width(6,8,9)
tOP
25
1000
ns
OE High Pulse Width(7)
tOP(ABS)
12
—
ns
Notes:
1. The output load is 30 pF.
2. The output load is 5 pF.
3. The tCE is applicable if OE is brought to Low before CE1r goes Low and is also applicable if actual value of both
or either tASO or tCLOL is shorter than specified value.
4. Applicable only to A0 and A1 when both CE1r and OE are kept at Low for the address access.
5. Applicable if OE is brought to Low before CE1r goes Low.
6. The tASO, tCLOL (Min) and tOP (Min) are reference values when the access time is determined by tOE.
If the actual value of each parameter is shorter than the specified minimum value, tOE becomes longer by the amount
of subtracting actual value from specified minimum value.
For example, if actual tASO, tASO (actual) , is shorter than specified minimum value, tASO (Min) , during OE control
access (i.e., CE1r stays Low) , the tOE becomes tOE (Max) + tASO (Min) - tASO (actual) .
7. The tASO[ABS] and tOP[ABS] are the absolute minimum values during OE control access.
8. If actual value of either tCLOL or tOP is shorter than specified minimum value, both tOLAH and tOLCH become tRC (Min)
- tCLOL (actual) or tRC (Min) - tOP (actual) .
9. Maximum value is applicable if CE1r is kept at Low.
38