TDA5235 Datasheet, PDF (195/259 Pages) Infineon Technologies AG – Enhanced Sensitivity Double-Configuration Receiver with Digital Baseband Processing | |||
|
◁ |
TDA5235
Appendix
Register Description
Field
Bits
TOTIMTSI
7:0
Type
w
EOM Timeout Timer Register
Description
Set value of Time-Out Timer (Telegram Start Identifier)
Timer is used to get back from Run Mode Self Polling to the Self Polling
Mode whenever a Symbol Synchronisation is available but there is no TSI
detected.
Timer is set back at new cycle start of Run Mode Self Polling.
TimeOut= (TOTIMTSI * 64 * 512) / fsys
Min: 01h = (1 * 64 * 512)/ fsys
Max: FFh= (255 * 64 * 512) / fsys
00h: disabled
Reset: 00H
A_TOTIM_EOM
EOM Timeout Timer Register
Offset
029H
727,0(20
Z
Reset Value
00H
Field
Bits
TOTIMEOM 7:0
Type
w
Description
Set value of Time-Out Timer (End of Message)
Timer is used to get back from Run Mode Self Polling to the Self Polling
Mode whenever a TSI has been detected but there is no EOM detected.
Timer is set back at new cycle start of Run Mode Self Polling.
TimeOut= (TOTIMEOM * 64 * 512 * 2) / fsys
Min: 01h = (1 * 64 * 512 * 2)/ fsys
Max: FFh= (255 * 64 * 512 * 2) / fsys
00h: disabled
Reset: 00H
AFC Limit Configuration Register
A_AFCLIMIT
AFC Limit Configuration Register
Data Sheet
8186('
Offset
02AH
195
Reset Value
02H
$)&/,0,7
Z
V1.0, 2010-02-19
|
▷ |