Register Description
Field
Bits
SYSRCTO 7:0
Type
w
SYNC Timeout Timer Register
Description
Synchronization search time out
FFh: 15 15/16 bit
00h: 0 bit
Reset: 87H
A_TOTIM_SYNC
SYNC Timeout Timer Register

Offset
027H
727,06<1&
Z
Reset Value
FFH

Field
Bits
TOTIMSYNC 7:0
Type
w
TSI Timeout Timer Register
Description
Set value of Time-Out Timer (Symbol Synchronization)
Timer is used to get back from Run Mode Self Polling to the Self Polling
Mode whenever there is no Symbol Synchronization.
Timer is set back at new cycle start of Run Mode Self Polling.
TimeOut= (TOTIMSYNC * 64 * 512) / fsys
Min: 01h = (1 * 64 * 512)/ fsys
Max: FFh= (255 * 64 * 512) / fsys
00h: disabled
Reset: FFH
A_TOTIM_TSI
TSI Timeout Timer Register

Offset
028H
727,076,
Z
Reset Value
00H

Data Sheet
194