English
Language : 

ICS1892 Datasheet, PDF (67/148 Pages) Integrated Circuit Systems – 10Base-T/100Base-TX Integrated PHYceiver
ICS1892
Chapter 8 Management Register Set
8.3.2 100Base-TX Full Duplex (bit 1.14)
The STA reads this bit to learn if the ICS1892 can support 100Base-TX, Full Duplex operations. The
ISO/IEC specification requires that the ICS1892 must set bit 1.14 to logic:
• Zero if it cannot support 100Base-TX, full-duplex operations.
• One if it can support 100Base-TX, full-duplex operations. (For the ICS1892, the default value of bit 1.14
is logic one. Therefore, when an STA reads the Status Register, the STA is informed that the ICS1892
supports 100Base-TX, full-duplex operations.)
This bit 1.14 is a Command Override Write bit, which allows an STA to alter the default value of this bit.
[See the description of bit 16.15, the Command Override Write Enable bit, in Section 8.11, “Register 16:
Extended Control Register”.]
8.3.3 100Base-TX Half Duplex (bit 1.13)
The STA reads this bit to learn if the ICS1892 can support 100Base-TX, half-duplex operations. The
ISO/IEC specification requires that the ICS1892 must set bit 1.13 to logic:
• Zero if it cannot support 100Base-TX, half-duplex operations.
• One if it can support 100Base-TX, half-duplex operations. (For the ICS1892, the default value of bit 1.13
is logic one. Therefore, when an STA reads the Status Register, the STA is informed that the ICS1892
supports 100Base-TX, half-duplex operations.)
This bit 1.13 is a Command Override Write bit, which allows an STA to alter the default value of this bit.
[See the description of bit 16.15, the Command Override Write Enable bit, in Section 8.11, “Register 16:
Extended Control Register”.]
8.3.4 10Base-T Full Duplex (bit 1.12)
The STA reads this bit to learn if the ICS1892 can support 10Base-T, full-duplex operations. The ISO/IEC
specification requires that the ICS1892 must set bit 1.12 to logic:
• Zero if it cannot support 10Base-T, full-duplex operations.
• One if it can support 10Base-T, full-duplex operations. (For the ICS1892, the default value of bit 1.12 is
logic one. Therefore, when an STA reads the Status Register, the STA is informed that the ICS1892
supports 10Base-T, full-duplex operations.)
This bit 1.12 is a Command Override Write bit, which allows an STA to alter the default value of this bit.
[See the description of bit 16.15, the Command Override Write Enable bit, in Section 8.11, “Register 16:
Extended Control Register”.]
8.3.5 10Base-T Half Duplex (bit 1.11)
The STA reads this bit to learn if the ICS1892 can support 10Base-T, half-duplex operations. The ISO/IEC
specification requires that the ICS1892 must set bit 1.11 to logic:
• Zero if it cannot support 10Base-T, half-duplex operations.
• One if it can support 10Base-T, half-duplex operations. (For the ICS1892, the default value of bit 1.11 is
logic one. Therefore, when an STA reads the Status Register, the STA is informed that the ICS1892
supports 10Base-T, half-duplex operations.)
Bit 1.11 of the ICS1892 Status Register is a Command Override Write bit., which allows an STA to alter the
default value of this bit. [See the description of bit 16.15, the Command Override Write Enable bit, in
Section 8.11, “Register 16: Extended Control Register”.]
ICS1892, Rev. D, 2/26/01
© 2000-2001, Integrated Circuit Systems, Inc.
All rights reserved.
67
February 26, 2001