Chapter 10 DC and AC Operating Conditions
10.5.6 MII / 100M Stream Interface: Synchronous Receive Timing
Table 10-13 lists the significant time periods for the MII / 100M Stream Interface synchronous receive
timing (which consists of timings of signals on the RXD[3:0], RXDV, RXER, and RXCLK pins). Figure 10-6
shows the timing diagram for the time periods.
Table 10-13. MII / 100M Stream Interface: Synchronous Receive Timing
Time
Period
Parameter
Conditions Min. Typ. Max. Units
t1 RXD[3:0], RXDV, RXER Setup to RXCLK Rise
–
10.0 –
–
ns
t2 RXD[3:0], RXDV, RXER Hold after RXCLK Rise
–
10.0 –
–
ns
Figure 10-6. MII / 100M Stream Interface Synchronous Receive Timing Diagram
RXCLK
RXD[3:0]
RXEN
RXER
t1
t2