ICS1892 Data Sheet
Chapter 8 Management Register Set
8.14.5 Automatic 10Base-T Power-Down (bit 19.1)
The Automatic 10Base-T Power Down bit provides an STA the means of enabling the ICS1892 to
automatically shut down 10Base-T support functions when 100Base-TX operations are being employed.
When this bit is set to logic:
• Zero, the 10Base-T Transceiver does not power down automatically in 100Base-TX mode.
• One, and the ICS1892 is operating in 100Base-TX mode, the 10Base-T Transceiver automatically turns
off to reduce the overall power consumption of the ICS1892.
Note: There are other means of powering down the 10Base-T Transceiver (for example, when the entire
device is isolated, using bit 0:10).
8.14.6 Automatic 100Base-TX Power-Down (bit 19.0)
The Automatic 100Base-TX Power Down bit provides an STA with the means of enabling the ICS1892 to
automatically shut down 100Base-TX support functions when 10Base-T operations are being employed.
When this bit is set to logic:
• Zero, the 100Base-TX Transceiver does not power down automatically in 100Base-TX mode.
• One, and the ICS1892 is operating in 10Base-T mode, the 100Base-TX Transceiver automatically turns
off to reduce the overall power consumption of the ICS1892.
Note: There are other means of powering down the 100Base-TX Transceiver (for example, when the
entire device is isolated using bit 0:10).
ICS1892, Rev. D, 2/26/01
© 2000-2001, Integrated Circuit Systems, Inc.
All rights reserved.
100