Ethernet Controller
Bit/Field
8
7
6:0
Name
DUPLEX
COLT
reserved
Type
R/W
R/W
R/W
Reset
1
0
0x00
Description
Set Duplex Mode
1: Enables the Full-Duplex mode of operation. This bit can be set by
software in a manual configuration process or by the Auto-Negotiation
process.
0: Enables the Half-Duplex mode of operation.
Collision Test
When set, enables the Collision Test mode of operation. The COLT bit
asserts after the initiation of a transmission and de-asserts once the
transmission is halted.
Write as 0, ignore on read.